CFMCalc

About CFMCalc

Size an air compressor from the tools you run, with duty cycle, tank runtime, and the difference between displacement CFM and the SCFM you get.

Who writes and checks this site

Alex Motor, Editor and calculator builder. Alex builds and maintains the calculators on CFMCalc and checks each guide against the sources it cites. Corrections go to boldwebdevelopment@gmail.com.

The figures in the guides are computed from the same code and data the site's tools use, so a guide cannot disagree with the tool it explains. A corrected guide shows the date it was updated.

What the tools are built on

  • Air tool consumption is published at 90 PSI, and a compressor delivers more air at lower pressure and less at higher, in proportion to absolute pressure.
  • Displacement CFM is the theoretical swept volume of the pump, and a single-stage compressor actually delivers only about 70 percent of it as SCFM.
  • Duty cycle decides sizing: an impact wrench draws 4.5 CFM but runs about 20 percent of the time, while a sander draws 6 CFM continuously and needs a compressor that covers all of it.
  • A 60 gallon tank cycling between 150 and 100 PSI stores about 27 cubic feet of free air, which covers a 5 CFM shortfall for roughly five and a half minutes.
  • Conventional practice adds a 25 to 50 percent margin over calculated demand for leaks, hose losses and optimistic tool ratings.
  • Continuous-use tools such as sanders and grinders are what oversize a compressor, not intermittent ones such as nailers and impact wrenches.

How this site is built

It is a static website. Every page is a pre-built file served from a content delivery network, and every calculation runs in your browser using JavaScript you can read. There is no account system, no server holding your inputs, and no paid API being called while you wait.

How it is funded

Affiliate links, disclosed where they appear.

Contact: boldwebdevelopment@gmail.com.

Where the numbers come from

  • Nailer manuals for air use per drive: DeWalt D51257, D51276, D51321 and D51823, and Ridgid R213BNA
  • Paslode F-350S published air consumption per shot at 90 and 120 PSI
  • Colorado State University Extension, sprinkler system blowout guidance
  • Hunter Industries, sprinkler blowout pressure guidance

What this site does not do

  • It does not collect your data, and has no way to.
  • It does not give professional advice. See the disclaimer.
  • It does not claim to be complete: where a question is out of scope, the page says so.